You are here:

DOLD UF 6925 – Emergency stop module

Brand
DOLD
Part number
UF 6925
Order number
0067556

Emergency stop module

  • For safety applications up to PL e / Cat. 4 e.g. SIL 3
  • Space saving
  • Connection front side
  • Manual or automatic start
  • Can be used also for safety gate
Category: SKU: DOLD-0067556 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

17.5 mm

Cat. / PL (EN ISO 13849-1)

4/e

SIL (IEC/EN 62061)

3

Supply voltage type

DC

Output contacts

3 NO contacts

Approvals

UL

Connection

Front side cage clamp terminals

Order number

0067556

The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e-stop buttons and safety gates.

Features

  • Corresponds to- PL e and category 4 according to EN ISO 13849-1- SIL 3 according to EN 61508- maximum SIL 3 according to EN IEC 62061
  • Can be used in applications:- According to EN 61511- According to EN 50156-1 for furnaces
  • 2-channel operation
  • Forcibly guided output contacts
  • With or without cross fault monitoring in the E-stop loop, switch S1
  • Manual restart or automatic restart, switch S2
  • LED indicator for channel 1, 2 and Netz
  • Width 17,5 mm

Technical specifications

1- / 2-channel 2
Approvals UL
Cat. / PL acc. to EN ISO 13849-1 4/e
Connection Front side cage clamp terminals
Cross fault detection Yes
Nominal voltage DC
Output contacts max. 3 NO contacts
SIL CL acc. to IEC/EN 62061 3
SIL acc. to IEC/EN 62061 3
Suited as safety gate monitor Yes
Thermal current Ith max. 8 A
Width 17,5 mm
Type UF 6925

Available variants

Contact equipping 3 NO contacts · 2 NO contacts, 1 NC contact · 2 NO contacts
Nominal voltage DC 8 – 36 V · DC 24 V
Approvals and Markings UL-listed C/US, TÜV
Variant Switching capacity standard. Start-Mode adjustable. Cross fault detection adjustable · Switching capacity standard. Start-Mode auto-start. Without cross fault detection · Switching capacity standard. Start-Mode auto-start. With cross fault detection · Switching capacity standard. Start-Mode manual-start. Without cross fault detection · Switching capacity standard. Start-Mode manual-start. With cross fault detection · Switching capacity for small loads. Start-Mode adjustable. Cross fault detection adjustable

Tell us the variant you need in your quote request.

Downloads