You are here:

DOLD UH 5892 – Insulation monitor

Brand
DOLD
Part number
UH 5892
Order number
0066309

Insulation monitor

  • Preventive fire and system protection
  • Insulation monitoring of DC voltage systems up to 600 V nominal voltage
  • No additional coupling device required
  • Suitable for leakage capacitances up to 20 μF
  • Monitoring also with voltage-free mains
Category: SKU: DOLD-0066309 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

45 mm

Enclosure design

Switch cabinet

Order number

0066309

The insulation monitor UH 5892 of the series varimeter IMD monitors the ground resistance of  isolated DC-voltage systems (IT-systems) with nominal voltage up to DC 600 V. The unit detects symmetrical as well as unsymmetrical faults. The separate auxiliary supply of AC/DC 24…60 V or AC/DC 85…230 V allows also monitoring when the system is without voltage. To indicate the actual ground resistance value the unit has an LED chain and an analogue output. When a fault is detected the relay switches and the red LED Alarm lights up, The device can be used for system with leakage capacities up to 20 uF.

Features

  • Insulation monitoring according to IEC/EN 61557-8
  • Detection of symmetric and asymmetric insulation faults
  • 1 changeover contact for alarm
  • Fixed response value RAN: 50 kΩ, other on request
  • Internal reset and test pushbutton
  • External test and reset pushbutton can be connected
  • LED indicator for auxiliary voltage and alarm
  • LED chain to indicate the current insulation resistance
  • Automatic or manual reset, programmable
  • Analogue output for insulating value
  • External indicating instrument can be connected
  • Closed circuit operation
  • Open circuit operation on request
  • With pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals
  • Width 45 mm

Technical specifications

Auxiliary voltage AC/DC
Connection for indicator Yes
Earth fault indicator Yes
Enclosure design Switch cabinet
IMD type AC, AC/DC, DC
Nominal voltage IT system AC 0 – 400 V, DC 0 – 600 V
Response value 50 kΩ
Response value type Fixed
Width 45 mm
Type UH 5892

Available variants

Alarm value 10 kOhm · 30 kOhm · 50 kOhm · 100 kOhm · 440 kOhm
Auxiliary voltage AC/DC 24 – 60 V · AC/DC 85 – 230 V
Contact equipping 1 changeover contact
Terminal type plug in terminal blocks with cage clamp terminals · terminal block with screw terminals

Tell us the variant you need in your quote request.