You are here:

Insulation monitors

33 products

Insulation monitoring devices (IMD) continuously measure the insulation resistance of unearthed IT systems (AC, DC and AC/DC) against earth, so faults are found before they cause outages, fire or accidents.

Showing 1–24 of 33 results

DOLD IL 5880 – Insulation monitor

DOLD IL 5880 – Insulation monitor

35 mm

Insulation monitor

  • Preventive fire and system protection
  • For single and 3-phase AC-systems up to 0 … 500 V and 10 … 10000 Hz
  • Monitors also disconnected voltage systems
  • Easy adjustment of response values
DOLD IL 5881 – Insulation monitor

DOLD IL 5881 – Insulation monitor

35 mm

Insulation monitor

  • Preventive fire and system protection
  • For DC voltage systems up to 12 … 280 V
  • Wide voltage range of measuring input UN DC 12 … 280 V (on request DC 24 … 500 V with separate auxiliary supply, Measuring range 20 … 500 kΩ)
  • Easy adjustment of response value
  • Selective ground fault indication for L+ and L- allows fast fault finding
DOLD IP 5880 – Insulation monitor

DOLD IP 5880 – Insulation monitor

35 mm

Insulation monitor

  • Preventive fire and system protection
  • For single and 3-phase AC-systems up to 0 … 500 V and 10 … 10000 Hz
  • Monitors also disconnected voltage systems
  • Easy adjustment of response values
DOLD LK 5894 – Insulation monitor

DOLD LK 5894 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 690 V nominal voltage
  • Suitable for large leakage capacitances up to 1000 μF
  • Simplest setting via engaging rotary switches
DOLD LK 5895 – Insulation monitor

DOLD LK 5895 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
  • Simplest setting via engaging rotary switches
DOLD LK 5896 – Insulation monitor

DOLD LK 5896 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
  • Simplest setting via engaging rotary switches
DOLD LK 5896/900 – Insulation monitor

DOLD LK 5896/900 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • System for sequential monitoring of separated voltage systems, that can be coupled
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
DOLD RL 5881 – Insulation monitor

DOLD RL 5881 – Insulation monitor

35 mm

Insulation monitor

  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • For non-earthed DC voltage networks up to 300 V
  • Suitable for large leakage capacitances up to 30 μF
  • Monitoring also with voltage-free mains
DOLD RL 5889 – Insulation monitor

DOLD RL 5889 – Insulation monitor

35 mm

Insulation monitor

  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Universal application in non-earthed AC, DC, AC/DC networks up to max. 300 V
  • Suitable for large leakage capacitances up to 30 μF
  • Monitoring also with voltage-free mains
DOLD RN 5893 – Insulation monitor

DOLD RN 5893 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
DOLD RN 5893/100 – Insulation monitor

DOLD RN 5893/100 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • Universal application in non-earthed AC-, DC-, AC/DC networks up to AC max. 250 V resp. DC max. 300 V
  • Connection of an external coupling device RP 5898 for voltages up to AC 690 V / DC 1000 V possible
  • Extended operating temperature range of – 40 … + 70 °C
DOLD RN 5897 – Insulation monitor

DOLD RN 5897 – Insulation monitor

52.5 mm

Insulation monitor

  • Acc. to DIN VDE 0100-551 for mobile generator sets
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to 300 V
DOLD RN 5897/010 – Insulation monitor

DOLD RN 5897/010 – Insulation monitor

52.5 mm

Insulation monitor

  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
  • With connection facility of an external coupling device:RL 5898 for voltages up to AC 400 V / DC 500 VRP 5898 for voltages up to AC 690 V / DC 1000 VRR 5898*) for voltages up to AC 1000 V / DC 1500 V
DOLD RN 5897/011 – Insulation monitor

DOLD RN 5897/011 – Insulation monitor

52.5 mm

Insulation monitor

  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
  • With connection facility of an external coupling device:RL 5898 for voltages up to AC 400 V / DC 500 VRP 5898 for voltages up to AC 690 V / DC 1000 VRR 5898*) for voltages up to AC 1000 V / DC 1500 V
DOLD RN 5897/020 – Insulation monitor

DOLD RN 5897/020 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • With connection facility of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V
  • Very fast reaction time ≤ 1 s
  • Optimised insulation resistance monitoring also during mains voltage variation
DOLD RN 5897/021 – Insulation monitor

DOLD RN 5897/021 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V

VARIMETER IMD insulation monitoring devices for unearthed IT power systems

In an unearthed power supply, known as an IT system, an insulation monitoring device (IMD) continuously measures the insulation resistance of the network against earth. Use of an IMD in IT systems is required under the "Safety of Machinery" standard. The goal is to stop insulation faults from turning into accidents, equipment failures or fires, while giving maintenance staff warning before a fault takes the system down.

DOLD's VARIMETER IMD devices are offered for DC, AC and three-phase networks as well as mixed AC/DC supplies. Typical applications include monitoring loads while they are switched off, mobile power generation, eMobility and DC networks, and medically used rooms. Because they can check drive components even when idle, they help prevent unplanned drive failures that would otherwise stop a machine or a whole plant.

For electric vehicle charging, the RN 5897/020 is designed for DC charging stations under IEC/EN 61851-23. During charging, the station and vehicle form an unearthed DC system with voltages up to 1000 V, and the IMD supervises insulation from the charger right into the vehicle so the user is never exposed to that voltage.

  • For DC, AC, three-phase and mixed AC/DC IT systems
  • RN 5897/020 for DC charging stations per IEC/EN 61851-23
  • Monitors switched-off loads and idle drive components
  • Suited to mobile generation, eMobility and medical rooms
  • Early fault detection improves fire safety and uptime