DOLD LK 5896 – Insulation monitor

Brand
DOLD
Part number
LK 5896
Order number
0065131

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
  • Simplest setting via engaging rotary switches
Category: SKU: DOLD-0065131 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

90 mm

Approvals

UL

Enclosure design

Switch cabinet

Order number

0065131

The insulation monitor LK 5896 of the VARIMETER IMD family is a solution for optimal insulation monitoring of modern IT systems. The device can be used in the most flexible way for AC, DC and AC/DC systems even with large leakage capacity to earth (PE). The adjustment of the setting values is simple and user friendly done on 2 rotary switches on the front of the device. Via LEDs the measured value, device parameters and device status are indicated easy to read. The unit has 3 relay contacts to signal Insulation and device failures. The analogue output provides a voltage and current signal proportional to the actual insulation resistance, which can be connected to a superior control (plc), another system or external display unit. In addition the LK 5896 provides a second measuring circuit that can be used to monitor an inverter on the AC side also when the inverter is disconnected.

Features

  • Insulation monitoring according to IEC/EN 61557-8
  • Detection of symmetric and asymmetric insulation faults
  • Measuring circuits can be disconnected via control terminals, e.g. for mains couplings
  • 1 changeover contact each for prewarning and alarm
  • 3. output relay for signalling wire break and device faults
  • Prewarning threshold setting range: 20 kΩ … 2 MΩ
  • Alarm threshold setting range: 1 kΩ … 250 kΩ
  • Energized or de-energized on trip can be selected for output relay
  • Setting the maximum leakage capacitance to shorten the response time
  • Simple, clearly arranged adjustment of the device with screwdriver
  • LED chain to indicate the current insulation resistance
  • Display of active measuring circuits
  • Automatic and manual device self-test
  • Alarm storage selectable
  • External test and reset pushbutton can be connected
  • Width: 90 mm

Technical specifications

Approvals UL
Auxiliary voltage DC
Classification For photovoltaic systems
Connection for indicator Yes
Earth fault indicator Yes
Enclosure design Switch cabinet
IMD type AC, AC/DC, DC
Nominal voltage IT system AC 0 – 1000 V, DC 0 – 1000 V
Response value 1 – 250 kΩ
Response value type Adjustable
Width 90 mm
Type LK 5896

Available variants

Alarm value 1 – 250 kOhm
Auxiliary voltage DC 24 V
Contact equipping 3 x 1 changeover contact
Prewarning value 20 kOhm – 2 MOhm
Approvals and Markings UL-listed C/US, UKCA
Variant Without wire-break detection at L(+)/L(-). With analog output. With auxiliary measuring circuit · With wire-break detection at L(+)/L(-). Analogue output with linear output function to indicate the insulation resistance value. With adapted measurement algorithm. With auxiliary measuring circuit · With wire-break detection at L(+)/L(-). Analogue output with linear output function to indicate the insulation resistance value. With auxiliary measuring circuit · With wire-break detection at L(+)/L(-). With analog output. With auxiliary measuring circuit

Tell us the variant you need in your quote request.