| Brand | DOLD |
|---|---|
| Housing width | 22.5 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | DC |
| Approvals | UL |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Order number | 0065424 |
DOLD UG 6960 – Multifunctional safety timer with instantaneous contacts
- Brand
- DOLD
- Part number
- UG 6960
- Order number
- 0065424
Multifunctional safety timer with instantaneous contacts
- Various delay functions adjustable at device:- Release delay- Release delay retriggerable- On delay- Fleeting on make / break- Delay function settable via potentiometer
- Various safety functions defined:- E-Stop- Safety gate- Two-hand control- Safety mat / Safety edge- Exclusive or contacts- Light curtain
- Manual or auto start
- Instantaneous contact and safety delayed contacts
- Protection against manipulation by sealable transparent cover
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The multifunction safety timer UG 6960 provides protection of men and machines by enabling and disabling a safety circuit. This is done by the adjusted time delay function. Simply select 1 out of 5 delay functions with a rotary switch – ready. The adjusted time is safe over the complete setting range. The UG 6960 is available for different safety functions. It has safe delayed and instantaneous contacts.
Features
- According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
- Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: 2 NO instantaneous contact and 2 NO contacts delayed
- 1 semiconductor output for instantaneous contacts1 semiconductor output for delayed contacts
- LED indicator for operation, safety function, time delay and failure
- As option with pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals
- Width: 22.5 mm
Technical specifications
| 1- / 2-channel | 2 |
|---|---|
| Application | Emergency stop, Light barrier, Safety gate, Safety mat, Two-hand |
| Approvals | UL |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Cross fault detection | Yes |
| Nominal voltage | DC |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Safe output contacts, redundant NO contacts | 4 |
| Thermal current Ith max. | 8 A |
| Width | 22,5 mm |
| Type | UG 6960 |
Available variants
| Contact equipping | 2 NO contacts instantaneous, 2 NO contacts delayed |
|---|---|
| Nominal voltage | DC 24 V |
| Terminal type | pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with cage clamp terminals 2-wire · pluggable terminal blocks with screw terminals |
| Time range | 3 s · 300 min · 300 s · 600 s |
| Approvals and Markings | UL-listed C/US, TÜV, UKCA |
| Variant | Safety function e-stop, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function e-stop, without cross fault detection. Delay function adjustable. Time delay adjustable · Safety function e-stop, without cross fault detection. Delay function adjustable. Time delay fixed · Safety function exclusive or contacts, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function light curtain, without cross fault detection. Delay function adjustable. Time delay adjustable · Safety function safety mat / Safety edge, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function two-hand control, with cross fault detection. Delay function adjustable. Time delay adjustable |
Tell us the variant you need in your quote request.