DOLD SK 9065 – Underload monitor (Cos-phi monitor)
- Brand
- DOLD
- Part number
- SK 9065
- Order number
- 0055816
Underload monitor (Cos-phi monitor)
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The underload monitor IK / SK / SL 9065 measures the phase shift between voltage and current. The phase angle changes with changing load. This measuring method is suitable to monitor asynchronous motors on underload and no load independent of motor size. The early detection of up-coming break downs and preventive maintenance avoid expensive damages. As user you profit from the reliability and availability of your plant.
Features
- According to EN 60255-1
- Detection of underload (cos ϕ)
- Without auxiliary supply
- Current up to 8 A Motors up to 5 A nominal current can be connected directly
- Higher currents via current transformer
- SL 9065CT with integrated current transformer for currents up to 100 A
- Adjustable response value
- Automatic reset (Alarm auto reset)
- Adjustable operate delay up to 100 s
- De-energized on trip
- For single and 3-phase loads e.g. motors
- Independent of phase sequence
- 1 changeover contact
- LED indicator voltage supply and alarm
- DIN rail or screw mounting
- Devices available in 2 enclosure versions:IK 9065: Depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43880SK 9065, SL 9065CT: Depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct
- IK 9065, SK 9065 width 17.5 mm
- SL 9065CT width 35 mmIK/SK 9065/100: as IK/SK 9065 but:
- Programmable for- Automatic reset or manual reset (latched alarm)- Energized or de-energized on trip
- With reset button
- Remote reset
Technical specifications
| 1- / 3-phase | 1, 3 |
|---|---|
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Measuring range max. | 8 A |
| Operate delay | Yes |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | SK 9065 |
Available variants
| Contact equipping | 1 changeover contact |
|---|---|
| Current range | 0,1 – 2 A · 0,4 – 8 A |
| Nominal voltage | 3AC 230 V · 3AC 400 V |
| Operate delay | 1 – 100 s |
| Variant | Without auxiliary supply. Manual reset programmable. Selection de-energized or energized on trip · Without auxiliary supply. Without alarm reset. De-energized on trip |
Tell us the variant you need in your quote request.