You are here:

DOLD BD 5935 – Emergency stop module

Brand
DOLD
Part number
BD 5935
Order number
0045453

Emergency stop module

  • Safe disconnection of electrical circuits
  • Line fault detection on ON pushbutton
  • Gold plated contacts to switch low loads (signal to PLC)
  • Optionally cross fault detection in emergency stop circuit
  • Easy exchange of devices by removable terminal strips
Category: SKU: DOLD-0045453 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

45 mm

Cat. / PL (EN ISO 13849-1)

4/e

SIL (IEC/EN 62061)

3

Supply voltage type

AC, DC

Output contacts

1 NC contact, 3 NO contacts

Approvals

UL-Recognized

Connection

Pluggable screw terminals

Order number

0045453

The BD 5935 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates.

Features

  • According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL 3) to IEC/EN 61508
  • 1- or 2-channel connection
  • Operating state display
  • LED display for channels 1 and 2
  • Overvoltage and short circuit protection
  • Wire connection: also 2 x 1.5 mm² stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm² stranded ferruled DIN 46228-1/-2/-3
  • Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts
  • Optionally automatic ON function or activation via the ON pushbutton
  • With fast auto start as option
  • Width 45 mm

Technical specifications

1- / 2-channel 1, 2
Approvals UL-Recognized
Cat. / PL acc. to EN ISO 13849-1 4/e
Connection Pluggable screw terminals
Cross fault detection Yes
Nominal voltage AC, DC
Output contacts max. 1 NC contact, 3 NO contacts
SIL CL acc. to IEC/EN 62061 3
SIL acc. to IEC/EN 62061 3
Suited as safety gate monitor Yes
Thermal current Ith max. 10 A
Width 45 mm
Type BD 5935

Available variants

Contact equipping 2 NO contacts, 2 NC contacts · 3 NO contacts, 1 NC contact
Nominal voltage AC 24 V 50/60 Hz · AC 48 V 50/60 Hz · AC 110 V 50/60 Hz · AC 115 V 50/60 Hz · AC 127 V 50/60 Hz · AC 230 V 50/60 Hz · AC 240 V 50/60 Hz · DC 24 V
Approvals and Markings TÜV, UKCA · TÜV, UKCA, CCC · UL-rec. C/US, TÜV, UKCA, CCC
Variant – · With fast auto start: typ. 110 ms, without line fault detection on ON-button