| Brand | DOLD |
|---|---|
| Housing width | 45 mm |
| Order number | 0061337 |
DOLD BA 9034N – Motor brake relay
- Brand
- DOLD
- Part number
- BA 9034N
- Order number
- 0061337
Motor brake relay
- Higher safety level and more economic by short stopping cycle
- Cost saving
- Compact design
- Easily appliance, no need for current measuring instrument
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The supply voltage is connected to terminals L1-L2 and the interlock contact X5-X6 closes to enable the motor contactor. A green LED indicates operation. The motor can be started with the start button. The braking DC-voltage is generated on terminals T1 and T2. The braking sequence is as follows: Pressing the stop button de-energises the motor contactor. The closing of X3-X4 (contact of the motor contactor) starts the braking. After a safety time the braking contactor closes for the adjusted braking time and the braking current flows through the motor.
Features
- According to IEC/EN 60947-4-2
- For all single and 3-phase asynchronous motors
- DC-brake with one way rectification up to max. 32 Aeff
- Controlled by microcontroller
- Easily fitted to existing installations
- Wear free and maintenance free
- Integrated braking contactor
- DIN-rail mounting
- Adjustable braking current (controlled current)
- With automatic standstill detection
- Variante /100- with braking time control- without detection of standstill
- Width: 45 mm
Technical specifications
| Automatic standstill monitoring | Yes |
|---|---|
| Braking current adjustable up to max. | 32 A |
| Braking time adjustable up to max. | 31 s |
| Signalling output | Yes |
| Width | 45 mm |
| Type | BA 9034N |
Available variants
| Braking current | 3 A · 10 A · 25 A · 32 A |
|---|---|
| Braking time | 1 – 15 s · 2 – 11 s · 2 – 31 s |
| Contact equipping | 1 changeover contact |
| Nominal voltage | AC 230 V · AC 400 V · AC 440 V · AC 480 V |
| Approvals and Markings | UKCA |
| Variant | Without standstill detection. Adjustable braking current. Adjustable braking time · With standstill detection. Adjustable braking current |
Tell us the variant you need in your quote request.