| Brand | DOLD |
|---|---|
| Housing width | 45 mm |
| Cat. / PL (EN ISO 13849-1) | 4/e |
| SIL (IEC/EN 62061) | 3 |
| Supply voltage type | AC, DC |
| Output contacts | 2 NO contacts |
| Approvals | UL-Recognized |
| Connection | Screw terminals |
| Order number | 0037332 |
DOLD BD 5987 – Emergency stop module
- Brand
- DOLD
- Part number
- BD 5987
- Order number
- 0037332
Emergency stop module
- Safe disconnection of electrical circuits
- Line fault detection at On pushbutton
- Gold-plated contacts to switch small loads (input for PLC)
- Optionally cross fault detection in emergency stop circuit
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The BD 5987 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates. The BD 5987.02/301 can be used as electronic replacement of a safety switch according to EN 81-20, section 5.11.2.2.
Features
- According to- PL e and category 4 to EN ISO 13849-1- maximum SIL 3 to EN IEC 62061- SIL 3 to EN 61508
- Output: 2 NO contacts for AC 250 V
- 1-channel or 2-channel connection
- LED displays for channels 1 and 2
- Overvoltage and short circuit protection
- Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Width 45 mm
- BD 5987._ _/001: same as BD 5987._ _ but
- Optionally automatic On function or after activation by the On pushbutton
- Optionally cross fault detection in emergency stop circuit
- BD 5987.02/301: same as BD 5987.02/001 but
- Suitable also for elevators according to EN 81-20/-50
- Complies to the requirements of the directive 2014/33/EU for elevators
- According to- PL d and category 3 to EN ISO 13849-1- maximum SIL 2 to EN IEC 62061- SIL 2 to EN 61508
- Shorter release time when opening the supply circuit
- Single-channel e-stop circuit
Technical specifications
| 1- / 2-channel | 1, 2 |
|---|---|
| Approvals | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1 | 4/e |
| Connection | Screw terminals |
| Cross fault detection | Yes |
| Nominal voltage | AC, DC |
| Output contacts max. | 2 NO contacts |
| SIL CL acc. to IEC/EN 62061 | 3 |
| SIL acc. to IEC/EN 62061 | 3 |
| Suited as safety gate monitor | Yes |
| Thermal current Ith max. | 10 A |
| Width | 45 mm |
| Type | BD 5987 |
Available variants
| Contact equipping | 2 NO contacts · 2 NO contacts, 1 signal contact |
|---|---|
| Nominal voltage | AC 24 V 50/60 Hz · AC 42 V 50/60 Hz · AC 48 V 50/60 Hz · AC 110 V 50/60 Hz · AC 127 V 50/60 Hz · AC 230 V 50/60 Hz · AC 240 V 50/60 Hz · DC 24 V |
| Approvals and Markings | TÜV |
| Variant | – · Optionally with cross fault detection in emergency stop circuit (application example M6904). Optionally automatic On function when operating voltage is applied or after activation by the On pushbutton · See BD 5987.03/001, but with special terminal designation · Starting behaviour as with BD 5987.02/001. Shorter release time when opening the supply circuit. Complies to the requirements of the directive 2014/33/EU for elevators · With 2 NO contacts, 1 signalling contact AC/DC 0,1 … 1 A / 10 …120 V |
Tell us the variant you need in your quote request.