You are here:

DOLD LG 7927 – Delay module, on delayed

Brand
DOLD
Part number
LG 7927
Order number
0062790

Delay module, on delayed

  • Easy to realise safe timing circuits
  • 4 forcibly guided output contacts at only 22.5 mm width
Category: SKU: DOLD-0062790 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

22.5 mm

Cat. / PL (EN ISO 13849-1)

3/d

SIL (IEC/EN 62061)

2

Supply voltage type

AC/DC

Output contacts

1 NC contact, 4 NO contacts

Approvals

UL

Connection

Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals

Order number

0062790

  • Delayed start or enabling of a movement.
  • Delayed enabling of a solenoid lock, e.g. SAFEMASTER STS

Features

  • Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:- Up to PL d and category 3 according to EN ISO 13849-1- Up to SIL 2 according to EN 61508 and EN 61511
  • Adjustable time delay
  • As option fixed time delay
  • High long life stability due to digital time base
  • Adjustable with or without cross fault detection
  • Output: 3 NO contacts + 1 NC contact + 1 forcibly guided
  • feedback contact or 4 NO contacts + 1 forcibly guided feedback contact
  • LED indicator for channel 1, 2 and operation voltage
  • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46228-1/-2/-3/-4
  • As option with pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals
  • Width 22.5 mm

Technical specifications

1- / 2-channel 1
Approvals UL
Cat. / PL acc. to EN ISO 13849-1 3/d
Connection Pluggable cage clamp terminals, Pluggable screw terminals, Screw terminals
Nominal voltage AC/DC
Output contacts max. 1 NC contact, 4 NO contacts
SIL CL acc. to IEC/EN 62061 2
SIL acc. to IEC/EN 62061 2
Thermal current Ith max. 5 A
Time delay max. 300 s
Width 22,5 mm
Type LG 7927

Available variants

Contact equipping 3 NO contacts, 2 NC contacts · 4 NO contacts, 1 NC contact
Nominal voltage AC/DC 24 V
Terminal type fixed terminal blocks with screw terminals · pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with screw terminals
Time range 0,1 – 1 s · 1 – 10 s · 3 – 30 s · 6 – 60 s · 30 – 300 s
Approvals and Markings UL-listed C/US, TÜV, CCC
Variant Time delay, adjustable

Tell us the variant you need in your quote request.

Downloads