| Brand | DOLD |
|---|---|
| Housing width | 35 mm |
| Output contacts | 1 C/O contact |
| Approvals | UL |
| Enclosure design | Distribution board |
| Phases | 1, 3 |
| Order number | 0066426 |
DOLD RL 9877 – Phase monitor
- Brand
- DOLD
- Part number
- RL 9877
- Order number
- 0066426
Phase monitor
- Preventive maintenance
- For better productivity
- Always right directions of motors and pumps
- Safe monitoring of motors and plants with phase failure detection
- High repeat accuracy
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The measuring relays RN 9877 and RL 9877 of the VARIMETER series monitor overvoltage, undervoltage, voltage range, phase asymmetry and phase sequence in 3-phase or single-phase systems. The measurement is very simple and without extensive wiring as there is no auxiliary power supply necessary. The monitoring functions are easily selectable using a single turn switch without complex menu structure. The early detection of up-coming break downs and preventive maintenance avoid expensive damages. As user you profit from the reliability and availability of your plant.
Features
- According to IEC/EN 60255-1
- For monitoring of AC 3- and single-phase with 50 /60 Hz
- Detection of- Overvoltage- Undervoltage- Voltage range excess- Phase failure- Phase asymmetry- Missing neutral e.g. broken neutral wire- And phase sequence in 3-phase systems
- With or without neutral
- Without separately auxiliary voltage (internal supply from all 3 phases)
- Output: 1 changeover contact
- De-energized on trip
- Adjustable hysteresis for reset
- Adjustable switching delay
- Fast fault detection
- Width:- RL 9877: 35 mm- RN 9877: 52.5 mm
Technical specifications
| 1- / 3-phase | 1, 3 |
|---|---|
| Approvals | UL |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Measuring range max. | 230 V |
| Output contacts | 1 C/O contact |
| Standard measuring range | 3/N AC 80 – 230 V / 45 – 130 V |
| Width | 35 mm |
| Type | RL 9877 |
Available variants
| Contact equipping | 1 changeover contact |
|---|---|
| Hysteresis | – · 4 – 20 % |
| Measuring voltage | 3/N AC 80 – 230 V · 3/N AC 80 – 230 V / 45 – 130 V · 3AC 80 – 230 V |
| Switching delay | 0 – 30 s |
| Approvals and Markings | UL-listed C/US |
| Variant | De-energized on trip. With neutral. Voltage monitoring · De-energized on trip. Without neutral. Voltage monitoring · Detect phase failure. Indications of the missing phase via LED. Can be used with or without neutral |
Tell us the variant you need in your quote request.