You are here:

DOLD RN 5897/300 – Insulation monitor

Brand
DOLD
Part number
RN 5897/300
Order number
0070148

Insulation monitor

  • For mobile generator sets according to DIN VDE 0100-551
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Universal application in non-earthed AC, DC, AC/DC networks up to max. 300 V
  • Easy adjustment of response values and setting parameter via rotational switch
Category: SKU: DOLD-0070148 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

52.5 mm

Approvals

UL

Enclosure design

Distribution board

Order number

0070148

The insulation monitor RN 5897/300 of the VARIMETER IMD family is a solution for optimal insulation monitoring of modern IT systems. The device can be used in the most flexible way for AC, DC and AC/DC systems. The adjustment of the setting values is simple and user friendly done on 3 rotary switches on the front of the device. Via multicolor LED the device status is indicated easy to read. With a sealable transparent cover the device is protectet against manipulation.

Features

  • Insulation monitoring according to IEC/EN 61557-8
  • 2 separate adjustable response thresholds (using e.g. for pre-Alarm and Alarm)
  • Setting range of 1st response value (Pre-Alarm): 20 kΩ … 1 MΩ:
  • Setting range of 2nd response value (Alarm): 10 kΩ … 250 kΩ
  • 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
  • Energized or de-energized on trip can be selected for indicator relay
  • LED for status indication
  • Automatic and manual device self-test
  • Alarm storage selectable
  • Protection against manipulation by sealable transparent cover
  • External control input for combined Test-/Reset-button
  • 3 wide voltage input for auxiliary voltage
  • Width 52.5 mm

Technical specifications

Approvals UL
Auxiliary voltage AC/DC, DC
Classification For mobile power generators
Earth fault indicator Yes
Enclosure design Distribution board
IMD type AC, AC/DC, DC
Nominal voltage IT system AC 0 – 230 V, DC 0 – 230 V
Response value 10 – 250 kΩ
Response value type Adjustable
Width 52,5 mm
Type RN 5897/300

Available variants

Alarm value 10 – 250 kOhm
Auxiliary voltage AC/DC 24 – 60 V · AC/DC 85 – 230 V · DC 12 – 24 V
Contact equipping 2 x 1 changeover contact
Prewarning value 20 kOhm – 1 MOhm
Approvals and Markings UL-listed C/US, CCC