You are here:

DOLD UG 6960 – Multifunctional safety timer with instantaneous contacts

Brand
DOLD
Part number
UG 6960
Order number
0065424

Multifunctional safety timer with instantaneous contacts

  • Various delay functions adjustable at device:- Release delay- Release delay retriggerable- On delay- Fleeting on make / break- Delay function settable via potentiometer
  • Various safety functions defined:- E-Stop- Safety gate- Two-hand control- Safety mat / Safety edge- Exclusive or contacts- Light curtain
  • Manual or auto start
  • Instantaneous contact and safety delayed contacts
  • Protection against manipulation by sealable transparent cover
Category: SKU: DOLD-0065424 Tags: Brand:
Download datasheet (PDF)Ask an engineer

Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.

Brand

DOLD

Housing width

22.5 mm

Cat. / PL (EN ISO 13849-1)

4/e

SIL (IEC/EN 62061)

3

Supply voltage type

DC

Approvals

UL

Connection

Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals

Order number

0065424

The multifunction safety timer UG 6960 provides protection of men and machines by enabling and disabling a safety circuit. This is done by the adjusted time delay function. Simply select 1 out of 5 delay functions with a rotary switch – ready. The adjusted time is safe over the complete setting range. The UG 6960 is available for different safety functions. It has safe delayed and instantaneous contacts.

Features

  • According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • Acc. to EN 50156-1 for furnaces
  • Line fault detection on On-button:
  • Manual restart or automatic restart
  • With or without cross fault monitoring
  • 2-channel
  • Forcibly guided output contacts
  • Output: 2 NO instantaneous contact and 2 NO contacts delayed
  • 1 semiconductor output for instantaneous contacts1 semiconductor output for delayed contacts
  • LED indicator for operation, safety function, time delay and failure
  • As option with pluggable terminal blocks for easy exchange of devices- with screw terminals- or with cage clamp terminals
  • Width: 22.5 mm

Technical specifications

1- / 2-channel 2
Application Emergency stop, Light barrier, Safety gate, Safety mat, Two-hand
Approvals UL
Cat. / PL acc. to EN ISO 13849-1 4/e
Connection Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals
Cross fault detection Yes
Nominal voltage DC
SIL CL acc. to IEC/EN 62061 3
SIL acc. to IEC/EN 62061 3
Safe output contacts, redundant NO contacts 4
Thermal current Ith max. 8 A
Width 22,5 mm
Type UG 6960

Available variants

Contact equipping 2 NO contacts instantaneous, 2 NO contacts delayed
Nominal voltage DC 24 V
Terminal type pluggable terminal blocks with cage clamp terminals · pluggable terminal blocks with cage clamp terminals 2-wire · pluggable terminal blocks with screw terminals
Time range 3 s · 300 min · 300 s · 600 s
Approvals and Markings UL-listed C/US, TÜV, UKCA
Variant Safety function e-stop, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function e-stop, without cross fault detection. Delay function adjustable. Time delay adjustable · Safety function e-stop, without cross fault detection. Delay function adjustable. Time delay fixed · Safety function exclusive or contacts, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function light curtain, without cross fault detection. Delay function adjustable. Time delay adjustable · Safety function safety mat / Safety edge, with cross fault detection. Delay function adjustable. Time delay adjustable · Safety function two-hand control, with cross fault detection. Delay function adjustable. Time delay adjustable

Tell us the variant you need in your quote request.

Downloads