| Brand | DOLD |
|---|---|
| Housing width | 22.5 mm |
| Approvals | UL |
| Phases | 3 |
| Order number | 0063850 |
DOLD UG 9256 – Smart motorstarter
- Brand
- DOLD
- Part number
- UG 9256
- Order number
- 0063850
Smart motorstarter
- Up to 6 function in one unit- Reversing anticlockwise- Reversing clockwise- Softstart- Softstop- Current monitoring or motor protection- Galvanic separation via forcibly guided contacts contact distance min. 0.5 mm
- 80 % less space
- Simple and time-saving commissioning as well as user-friendly operation through setting via potentiometers on absolute scales
- Blocking protection
- Hybrid relay combines benefits of relay technology with non-wearing semiconductor technology
Price and lead time on request — add this part to your quote list and we will reply with pricing and availability.
The smart motorstarter UG 9256 from the MINISTART series is a softstart, reversal and protection of 3-phase asynchronous motors. Overcurrent is detected when the set current is exceeded longer than 2 sec. Direction reversal takes place via relay switching. The relays are de-energised at this. This ensures a long service life.
Features
- According to IEC/EN 60947-4-2
- To reverse 3 phase motors from 30 W to 150 W resp. 90 W to 750 W resp. 550 W to 4 KW at AC 400 V
- 2-phase softstart
- Max. 4 potentiometer für setting of starting torque, deceleration torque, softstart /-stop, overcurrent limit or rated motor current
- 4 LEDs for status indication
- Reversing with relays without current, softstart, softstop with thyristor
- Galvanic separated 24V-inputs for clockwise- and anticlockwise
- Reset button on front
- Connection facility for external reset button
- Relay indicator output for operation
- Indicator output at customers specification (on request)
- Galvanic separation between control circuit and power circuit
- Width: 22.5 mm
Technical specifications
| 1- / 3-phase | 3 |
|---|---|
| Approvals | UL |
| Auxiliary voltage | DC 24 V |
| Load current up to | 9 A |
| Load voltage up to | 3AC 200 – 480 V |
| On/Off Input Control | DC |
| Signalling output | Yes |
| Temperature monitoring | Yes |
| Width | 22,5 mm |
| Type | UG 9256 |
Available variants
| Contact equipping | 1 changeover contact |
|---|---|
| Nominal current | 2 A · 9 A |
| Nominal voltage | 3AC 200 – 480 V |
| Ramp time | 0 – 1 s · 1 – 10 s · without |
| Approvals and Markings | UL-listed C/US, UKCA |
| Variant | Without softstart / softstop. Without mains isolating relay, on when no failure. Motor protection · With softstart. With mains isolating relay, on when no failure. Motor protection · With softstart. With mains isolating relay, on when no failure. Overcurrent protection · With softstart. Without mains isolating relay, on when no failure. Motor protection · With softstart. Without mains isolating relay, on when no failure. Overcurrent protection · With softstart. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. With mains isolating relay, on when no failure. Motor protection · With softstart. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. Without mains isolating relay, on when no failure. Motor protection · With softstart / softstop. With mains isolating relay, indicator relay on while bridging relay on. Overcurrent protection · With softstart / softstop. With mains isolating relay, on when no failure. Motor protection · With softstart / softstop. With mains isolating relay, on when no failure. Overcurrent protection · With softstart / softstop. Without mains isolating relay, indicator relay on while bridging relay on. Motor protection · With softstart / softstop. Without mains isolating relay, on when no failure. Overcurrent protection · With softstart / softstop. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. With mains isolating relay, on when no failure. Motor protection · With softstart / softstop. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. With mains isolating relay, on when no failure. Overcurrent protection · With softstart / softstop. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. Without mains isolating relay, indicator relay at beginning to softstart on till end of softstop. Motor protection · With softstart / softstop. With ramp off at time potentiometer ton/off 0 … 0,1 = without ramp. Without mains isolating relay, on when no failure. Overcurrent protection |
Tell us the variant you need in your quote request.