You are here:

All products

46 products
Application: Energy, storage & e-mobilityAbout this applicationClear ×

Showing 1–24 of 46 results

DOLD LK 5895 – Insulation monitor

DOLD LK 5895 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
  • Simplest setting via engaging rotary switches
DOLD LK 5896 – Insulation monitor

DOLD LK 5896 – Insulation monitor

90 mm

Insulation monitor

  • Preventive fire and system protection
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks with up to 1000 V nominal voltage
  • Suitable for large leakage capacitances up to 3000 μF
  • Simplest setting via engaging rotary switches
DOLD MH 9143 – Mains Frequency Monitor

DOLD MH 9143 – Mains Frequency Monitor

45 mm

Mains Frequency Monitor

  • Monitoring of 50 – and 60 Hz-current supply on over- and underfrequency
  • For precise frequency measuring with fast response time
  • High disturbance immunity
  • Separately adjustable trip points and separate outputs for overand underfrequency (1 or 2 c/o each)
DOLD MK 9143N – Mains Frequency Monitor

DOLD MK 9143N – Mains Frequency Monitor

22.5 mm

Mains Frequency Monitor

  • Monitoring of 50 – and 60 Hz-current supply on over- and underfrequency
  • For precise frequency measuring with fast response time
  • High disturbance immunity
  • Separately adjustable trip points and separate outputs for overand underfrequency (1 or 2 c/o each)
DOLD RN 5893 – Insulation monitor

DOLD RN 5893 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
DOLD RN 5893/100 – Insulation monitor

DOLD RN 5893/100 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • Universal application in non-earthed AC-, DC-, AC/DC networks up to AC max. 250 V resp. DC max. 300 V
  • Connection of an external coupling device RP 5898 for voltages up to AC 690 V / DC 1000 V possible
  • Extended operating temperature range of – 40 … + 70 °C
DOLD RN 5897/020 – Insulation monitor

DOLD RN 5897/020 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • With connection facility of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V
  • Very fast reaction time ≤ 1 s
  • Optimised insulation resistance monitoring also during mains voltage variation
DOLD RN 5897/021 – Insulation monitor

DOLD RN 5897/021 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Preventive fire and system protection
  • Detection of symmetric and asymmetric insulation faults
  • Quick fault localisation through selective earth fault detection to L+ and L-
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
DOLD RN 5897/240 – Insulation monitor

DOLD RN 5897/240 – Insulation monitor

52.5 mm

Insulation monitor

  • Insulation monitoring according to IEC/EN 61557-8
  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Universal application in non-earthed AC, DC, AC/DC networks up to AC max. 250 V or DC max. 300 V
  • With connection facility of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V
  • Extended operating temperature range of – 40 … + 70 °C
DOLD RN 5897/320 – Insulation monitor

DOLD RN 5897/320 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • Connection of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V
  • Extended operating temperature range of – 40 … + 70 °C
  • Very fast reaction time ≤ 1 s
DOLD RN 5897/321 – Insulation monitor

DOLD RN 5897/321 – Insulation monitor

52.5 mm

Insulation monitor

  • Suitable for DC charging stations for electric vehicles acc. to IEC/EN 61851-23:2014/AC:2016-06
  • Insulation monitoring according to IEC/EN 61557-8
  • Universal application in non-earthed AC-, DC-, AC/DC networks up to AC max. 250 V resp. DC max. 300 V
  • Connection of an external coupling device RL 5898 for voltages up to AC 400 V / DC 500 V or RP 5898 for voltages up to AC 690 V / DC 1000 V possible
  • Extended operating temperature range of – 40 … + 70 °C
DOLD RP 9811 – Voltage and frequency monitor

DOLD RP 9811 – Voltage and frequency monitor

70 mm

Voltage and frequency monitor

  • Mains and system protection for your generator set
  • Can be used in several countries- DIN VDE 0126-1-1:2013-08 (generator sets on public grid)- VDE-AR-N 4105:2011-08 (generator sets on public grid)- BDEW-directive:2008-06 (generator sets on medium voltage grid)- CEI 0-21:2012-06 (generator sets in Italy)- ÖVE/ÖNORM E8001-4-712:2009 (generator sets in Austria)- G59/3 (generator sets in UK)
  • Easy adjustment via rotational switch and menu display
  • Indication, diagnostics and fault presentation via display and LEDs
  • Password protected
DOLD RP 9812 – Voltage and frequency monitor

DOLD RP 9812 – Voltage and frequency monitor

70 mm

Voltage and frequency monitor

  • Mains and system protection for your generator set (NA protection)
  • Can be used in several countries- Generator sets on public grid according to VDE-AR-N 4105:2018-11- Generator sets on the medium voltage grid according to VDE-AR-N 4110:2023-09- Generator sets on the high voltage grid according to VDE-AR-N 4120:2018-11
  • Easy adjustment via rotational switch and menu display
  • Indication, diagnostics and fault presentation via display and LEDs
  • Password protected
DOLD UG 9075 – Fuse monitor

DOLD UG 9075 – Fuse monitor

22.5 mm

Fuse monitor

  • increasing the availability of plants by early detection of blown fuses, that may cause damage if undetected
  • fast detection of blown fuses also with disconnected load availability of your plant on request
  • reliable detection of blown fuses inspite of:- Asymmetric mains- Harmonic content
DOLD UG 9443 – Mains frequency monitor, for Modbus

DOLD UG 9443 – Mains frequency monitor, for Modbus

22.5 mm

Mains frequency monitor, for Modbus

  • Simple parameterization, monitoring and diagnosis
  • Compact design
  • Universal measuring input for AC voltages from AC 24 … 690 V
  • Auxiliary voltage ranges AC/DC 24 … 240 V
  • Early detection of irregularities
STEM s.r.l Battery charger NBCDC12V4B

STEM s.r.l Battery charger NBCDC12V4B

The NBCDC12V4B is a complete solution to use only one product to control and charge four 12V / 7.2 Ah lead-acid battery. The batteries are recharged and monitored independently even when they are connected in series. This product uses a DC power supply therefore it is particularly suitable in applications related to renewable energy such as photovoltaic cells.