Safety Mat Modules, DoldPCB,Safety,Relays,DoldPCB,Safety,Relays,DoldPCB,Safety,Relays,DoldPCB,Safety,Relays,Dold


Safety Mat Modules

Evaluation of safety mats These safeguard products generate a control command when exposed to an operating force and cause an immediate stop of a dangerous movement via an evaluator module.

Advantages

  • Specific adjustment to areas to be protected
  • Type-tested solutions in compliance with relevant norms
  • Permanent function monitoring of the safety mats

Technology

  • Breaking current limiting to <10 mA protects the safety mat againstelectrical damage due to overcurrent in the case of short-circuit
  • Rail-mounted modules
  • Automatic or manual activation function
  • Plug-type terminal blocks
  • Safetycategory 4 acc. to EN 954-1

Applications

Safety mats are safeguard products designed to protect large-area dangerous areas and to control access to machinery.

Safety-mat modules SAFEMASTER

Function
Cat. / PL
acc. to
EN 13849-1*
SIL CL
acc. to
EN 62061*
1-channel/
2-channel
Output contacts,
max.
nominal voltage
Thermal current
Ith [A] max.
Removable
terminals
Width [mm]
Type
DC
AC
Safety-mat module
4 / e
3
2
2 NO, 1 NC
or 3 NO
+
5 A
+
22.5

NO = normally open contact, NC = normally closed contact
* Please check state of approval of idividual devices in the latest data sheet.