Intrinsically,Safe,Sensors,Tippkemper Matrix GmbHIntrinsically,Safe,Sensors,Tippkemper Matrix GmbHIntrinsically,Safe,Sensors,Tippkemper Matrix GmbHIntrinsically,Safe,Sensors,Tippkemper Matrix GmbHIntrinsically,Safe,Sensors,Tippkemper Matrix GmbH


Intrinsically Safe Sensors From Tippkemper Matrix GmbH

Intrinsically safe optoelectronical sensors with 3-wire construction and NAMUR.

Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
  • for use in Ex-Zones 1, 2 / CL I, GR ABCD, CL II GR EFG, CL III HAZARDOUS LOCATIONS
  • type of Ex protection "intrinsically safe" EEx ia IIC T6
  • CLASSIFIED BY UNDERWRITERS LABORATORIES INC. ASSIGNED CONTROL No. 24VL.
  • ATEX certification DMT 03 ATEX E003

Intrinsically Safe Sensors

Intrinsically Safe Sensors

Intrinsically Safe Sensors

AX-T-5-P18/AX-T-10-P18
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M18

AX-T-5-P30/AX-T-10-P30
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M30

AX-SE-25-P18
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M18

AX-SE-25-P30/AX-SE-50-P30
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M30

AX-R-1-P18
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M18

AX-R-4-P30
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M30

Intrinsically safe proximity switches with 3-wire construction type series AX-T

  • for use in Ex zones 1 + 2
  • type of Ex protection "intrinsically safe" EEx ia IIC T6
  • Laser class 2 ("BG-Germany" approved - German social insurance against occupational accident))
  • very high EMC reliability
  • Classified by UL
  • Data sheet (PDF)

Intrinsically safe light barriers with 3-wire construction type series AX-SE

  • for use in Ex zones 1 + 2
  • type of Ex protection "intrinsically safe" EEx ia IIC T6
  • laser class 2 (BG approved - German social insurance against occupational accident)
  • very high EMC reliability
  • Classified by UL
  • data sheet (PDF)
  • EX-certification DMT ATEX (PDF)

Intrinsically safe reflection light barriers with 3-wire construction type series AX-R

  • for use in Ex zones 1 + 2
  • type of Ex protection "intrinsically safe" EEx ia IIC T6
  • laser class 2 (BG approved - German social insurance against occupational accident)
  • very high EMC reliability
  • Classified by UL
  • data sheet (PDF)
  • EX-certification DMT ATEX (PDF)

Intrinsically Safe Sensors

Intrinsically Safe Sensors

Intrinsically Safe Sensors

AXL-S/E-51
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M18

AXL-S/E-80
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
Housing M30

NEX-112-R/NEX-112-E
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
R - Relay output with additional adjustable
E - Opto-coupler output drop-in and drop-out delay

NEX-112-RZ/NEX-112-EZ
Intrinsically,Safe,Sensors,Tippkemper Matrix GmbH
R - Relay output with additional adjustable
E - Opto-coupler output drop-in and drop-out delay

Intrinsically safe laser light barriers type series AX-L

  • for use in Ex zones 1 + 2
  • type of protection "intrinsically safe" EEx ia IIC T6
  • laser class 2 (BG approved - German social insurance against occupational accident)
  • very high EMC reliability

Intrinsically safe power supply type series NEX-112

  • intrinsically safe power supply for connecting 3-wire and NAMUR EEx ia sensors
  • type of protection: intrinsically safe [EEx ia] IIC
  • listed by Underwriter's Laboratories Inc
  • Data sheet (PDF)
  • EU certification of conformity PTB 03 ATEX 2091

Intrinsically safe power supply type series NEX-112

  • intrinsically safe power supply for connecting 3-wire and NAMUR EEx ia sensors
  • type of protection: intrinsically safe [EEx ia] IIC
  • listed by Underwriter's Laboratories Inc
  • Data sheet (PDF)
  • EU certification of conformity PTB 03 ATEX 2091

Product Specification                

Type Series

Light barriers

AX-SE

Proximity switch

AX-T

Reflection light barriers

AX-R

Laser light barriers

AX-L

Power supplies for intrinsically safe circuit           

NEX



Site Designed And Maintained By Panther Marketing And Design