Special Sensors

You are here:

Independent to your demands or the used sensor technology, we develop and produce systems that are especially adapted to your application. Advantages: • Adaptation to your application • Simplification of Installation • Extended technical specification • Cost reduction

i

Tube Sensors

The tube sensor detects moving metallic pieces in hoses or ducts. In contrast to conventional ring sensors the hose sensor can be mounted much easier and faster – the customer saves time and space during installation. The sensors of the new generation work after the principle of dynamic, simultaneously and static. 

NameOrder numberOperationMountingDatasheet
Name KJ16-Q16KN-DPS-V1 Order number 08310000903Operation inductive tube sensorMounting non shieldedDatasheet
Name KJ10-Q16KN-DPS-V1 Order number 08310001105Operation inductive tube sensorMounting non shieldedDatasheet
Name KJ16-Q16KN-DPS-X1133 Order number 08310001928Operation inductive tube sensorMounting non shieldedDatasheet
Name KJ16-Q16KN-DPS-X0337 Order number 08310001891Operation inductive tube sensorMounting non shieldedDatasheet

|

Angle Sensors

Angle measuring contact-free.By using HALL-elements and separate magents these sensors detect angle moving up to 360°.Easy assembling and wide tolerances in moving applications.

NameOrder numberOperationMountingDatasheet
Name KW360-D42KN7-ANI-X0392 Order number 08330001135Operation angle sensorMounting non shieldedDatasheet
Name KW360-D42KN7-ANU5 Order number 08330001132Operation angle sensorMounting non shieldedDatasheet
Name KW360-D42KN7-ANI Order number 08330001140Operation angle sensorMounting non shieldedDatasheet
Name KW360-D42KN7-ANU Order number 08330001139Operation angle sensorMounting non shieldedDatasheet
Name KW360-D42KN7-ANU-X0392 Order number 08330001143Operation angle sensorMounting non shieldedDatasheet

|

Inclination Sensor

Inclination sensors detect the absolute deviation from a horizontal plane. This product group includes analog inclination sensors as well as the latest generation with CANOpen-connection, digital AC-switching outputs for the direct control of hydraulic valves or one- or two-axe design.

NameOrder numberOperationMountingDatasheet
Name KN60-Q40KN-ANI-V2 Order number 08330000080Operation inclination sensorMounting non shieldedDatasheet
Name KN20-Q40KN-ANI-V2 Order number 08330000108Operation inclination sensorMounting -Datasheet
Name KN45-Q40KN-ANU-V2 Order number 08330000075Operation inclination sensorMounting non shieldedDatasheet
Name KN90-Q40KN-ANU-V2 Order number 08330000095Operation inclination sensorMounting non shieldedDatasheet
Name KN15-Q40KN-ANU-V2 Order number 08330000107Operation inclination sensorMounting -Datasheet
Name KN5-Q40KN-ANU-V2 Order number 08330000066Operation inclination sensorMounting non shieldedDatasheet
Name KN30-Q40KN-ANU-V2 Order number 08330000500Operation inclination sensorMounting non shieldedDatasheet
Name KN60-Q40KN-ANU-V2 Order number 08330000501Operation inclination sensorMounting non shieldedDatasheet
Name KN75-Q40KN-ANU-V2 Order number 08330000502Operation inclination sensorMounting non shieldedDatasheet
Name KN5-Q40KN-ANI-V2 Order number 08330000087Operation inclination sensorMounting non shieldedDatasheet
Name KN15-Q40KN-ANI-V2 Order number 08330000503Operation inclination sensorMounting non shieldedDatasheet
Name KN30-Q40KN-ANI-V2 Order number 08330000504Operation inclination sensorMounting non shieldedDatasheet
Name KN45-Q40KN-ANI-V2 Order number 08330000067Operation inclination sensorMounting non shieldedDatasheet
Name KN75-Q40KN-ANI-V2 Order number 08330000505Operation inclination sensorMounting non shieldedDatasheet
Name KN90-Q40KN-ANI-V2 Order number 08330000076Operation inclination sensorMounting non shieldedDatasheet

|

Pressure resistant Sensors

By using a complete closed stainless steel face these sensor types are especially qualified for application in aggressive environmental, in hydraulik devices or in foodstuff industry. Pulsotronic offers pressure-resistant sensors generally with an extended temperature range and up to 500bar pressure resistance.

NameOrder numberOperationMountingDatasheet
Name KJD2-M12EB50-DPS-V2/500/14,9 Order number 08310002400Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB50-DPÖ-V2/500/14,9 Order number 08310002401Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB50-DPS-V2/500/17,9 Order number 08310002402Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB50-DPÖ-V2/500/17,9 Order number 08310002403Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB56-DPS-V2/500/14,9 Order number 08310001749Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB56-DPÖ-V2/500/14,9 Order number 08310002404Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB56-DPS-V2/500/17,9 Order number 08310001746Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB56-DPÖ-V2/500/17,9 Order number 08310002405Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPS-V2/500/14,9 Order number 08310002406Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPÖ-V2/500/14,9 Order number 08310002407Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPS-V2/500/17,9 Order number 08310002408Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPÖ-V2/500/17,9 Order number 08310002409Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB78-DPS-V2/500/14,9 Order number 08310002410Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB78-DPÖ-V2/500/14,9 Order number 08310002411Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB78-DPS-V2/500/17,9 Order number 08310001781Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD1,5-M12EB138-DPS-V2/300/22,5 Order number 08310001093Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPS-V2/500/12,9 Order number 08310001982Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB93-DPS-V2/500/12,9 Order number 08310002007Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB127-DPS-V2/500/12,9 Order number 08310002045Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB56-DPS-X0329/500/17,9 Order number 08310003812Operation inductive sensor pressure resistantMounting shieldedDatasheet
Name KJD2-M12EB69-DPÖ-V2/500/12,9 Order number 08310003515Operation inductive sensor pressure resistantMounting shieldedDatasheet

|

Acoustic Sensors

Acoustic sensors detect defined static noise or switch-sounds on machines, devices and plants. Due to protection class IP67, an enlarged operating temperature up to 85°C and an adjustable switching threshold these sensors even are proper for external applications.

NameOrder numberOperationMountingDatasheet
Name KA1-Q25KB-DPÖ Order number 08340001010Operation acoustic sensorMounting non shieldedDatasheet

|

High Temperature Sensors

Sensors for applications that require an enlarged operating temperature range from -40°C … 180°C. These sensors are especially used in applications that demand a high dependability in extreme temperatures like in steel mills, blast furnaces and in the food industry.

NameOrder numberOperationMountingDatasheet
Name KJ2-M8EB60-DPS-HT140-X0240 Order number 08310001715Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ3-M12EB60-DPS-HT150-X0202 Order number 08310000812Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ15-M30EN80-DPS-HT180-X0202 Order number 08310000920Operation inductive sensor high temperatureMounting non shieldedDatasheet
Name KJ2-M8EB60-DPS-HT140-X0202 Order number 08310000959Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ5-M18EB70-DPS-HT180-X0202 Order number 08310001716Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ10-M30EB70-DPS-HT180-X0240 Order number 08310001728Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ8-M18EN80-DPS-HT180-X0202 Order number 08310001737Operation inductive sensor high temperatureMounting non shieldedDatasheet
Name KJ3-M12EB60-DPS-HT150-X0240 Order number 08310002500Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ4-M12EN60-DPS-HT150-X0240 Order number 08310002501Operation inductive sensor high temperatureMounting non shieldedDatasheet
Name KJ4-M12EN60-DPS-HT150-X0202 Order number 08310002502Operation inductive sensor high temperatureMounting non shieldedDatasheet
Name KJ5-M18EB70-DPS-HT180-X0240 Order number 08310002503Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ8-M18EN80-DPS-HT180-X0240 Order number 08310002504Operation inductive sensor high temperatureMounting non shieldedDatasheet
Name KJ10-M30EB70-DPS-HT180-X0202 Order number 08310002505Operation inductive sensor high temperatureMounting shieldedDatasheet
Name KJ15-M30EN80-DPS-HT180-X0240 Order number 08310002506Operation inductive sensor high temperatureMounting non shieldedDatasheet

|

Extended Temperature Sensors

Sensors for applications that require an enlarged operating temperature range from -40°C … 100°C. Customized sensors for temperature ranges beyond 100°C as requested.

NameOrder numberOperationMountingDatasheet
Name KJ2-M12MB40-DPS-T Order number 08317626010Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ2-M12MB60-DPS-V2-T Order number 08317626065Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ4-M12MN40-DPS-T Order number 08317626110Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ5-M18MB40-DPS-T Order number 08317646010Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ5-M18MB65-DPS-V2-T Order number 08317646065Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ8-M18MN40-DPS-T Order number 08317646110Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ8-M18MN65-DPS-V2-T Order number 08317646165Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ10-M30MB40-DPS-T Order number 08317666010Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ10-M30MB60-DPS-V2-T Order number 08317666065Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ15-M30MN40-DPS-T Order number 08317666110Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ15-M30MN60-DPS-V2-T Order number 08317666165Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ1,5-M8MB45-DPS-T Order number 08317616010Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ4-M12MN60-DPS-V2-T Order number 08316626165Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ2-M12MB40-DPS-T-X0309 Order number 08317626012Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ2-M12MB70-DPS-T-X0309 Order number 08317626031Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ4-M12MN40-DPS-T-X0309 Order number 08317626112Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ10-M30MB40-DPS-T-X0309 Order number 08317666012Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ15-M30MN40-DPS-T-X0309 Order number 08317666112Operation inductive sensor temperature immuneMounting non shieldedDatasheet
Name KJ1,5-M8MB45-DPS-T-X0309 Order number 08310001701Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ1,5-M8MB50-DPS-V1-T Order number 08317616034Operation inductive sensor temperature immuneMounting shieldedDatasheet
Name KJ4-M12MN40-DNS-T-X0303 Order number 08317626310Operation inductive sensor temperature immuneMounting non shieldedDatasheet

|

Weld Field immune Sensors

By reason of the special protection of the sensor electronics weld field immune sensors are used on or close to welding machines. The housing is tefloncoated and protects against welding beats and spark erosion.

NameOrder numberOperationMountingDatasheet
Name KJ2-M12MB50-DPS-SF Order number 08317625840Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ2-M12MB70-DPS-V2-SF Order number 08317625845Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ4-M12MN50-DPS-SF Order number 08317625900Operation inductive sensor weld immuneMounting non shieldedDatasheet
Name KJ4-M12MN70-DPS-V2-SF Order number 08317625965Operation inductive sensor weld immuneMounting non shieldedDatasheet
Name KJ5-M18MB60-DPS-SF Order number 08317645840Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ5-M18MB80-DPS-V2-SF Order number 08317645845Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ8-M18MN60-DPS-SF Order number 08317645900Operation inductive sensor weld immuneMounting non shieldedDatasheet
Name KJ10-M30MB60-DPS-SF Order number 08317665840Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ10-M30MB80-DPS-V2-SF Order number 08317665845Operation inductive sensor weld immuneMounting shieldedDatasheet
Name KJ15-M30MN60-DPS-SF Order number 08317665900Operation inductive sensor weld immuneMounting non shieldedDatasheet
Name KJ15-M30MN80-DPS-V2-SF Order number 08317665965Operation inductive sensor weld immuneMounting non shieldedDatasheet
Name KJ8-M18MN80-DPS-V2-SF Order number 08317645965Operation inductive sensor weld immuneMounting non shieldedDatasheet

|

Full Metal Sensors

Due to their stainless steel housing metal face sensors are ideal for applications in aggressive media, oils or acids, and in alkaline fluids. The sensor field permeats the stainless steel sensor front and detects ferrous metals in standard switching distances.

NameOrder numberOperationMountingDatasheet
Name SJD2-M12EB50-DPS Order number 08313121210Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DPS-V2 Order number 08313121211Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB50-DPÖ Order number 08313121220Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DPÖ-V2 Order number 08313121221Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB50-DNS Order number 08313121230Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DNS-V2 Order number 08313121231Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB50-DNÖ Order number 08313121240Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DNÖ-V2 Order number 08313121241Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB50-DPA Order number 08313121250Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DPA-V2 Order number 08313121251Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB50-DNA Order number 08313121260Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M12EB68-DNA-V2 Order number 08313121261Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DPS Order number 08313181510Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB80-DPS-V2 Order number 08313181511Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DPÖ Order number 08313181520Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB80-DPÖ-V2 Order number 08313181521Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DNS Order number 08313181530Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB76-DNS-V2 Order number 08313181531Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DNÖ Order number 08313181540Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB80-DNÖ-V2 Order number 08313181541Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DPA Order number 08313181550Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB80-DPA-V2 Order number 08313181551Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB55-DNA Order number 08313181560Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD5-M18EB80-DNA-V2 Order number 08313181561Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DPS Order number 08313301110Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DPS-V2 Order number 08313301111Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DPÖ Order number 08313301120Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DPÖ-V2 Order number 08313301121Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DNS Order number 08313301130Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DNS-V2 Order number 08313301131Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DNÖ Order number 08313301140Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DNÖ-V2 Order number 08313301141Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DPA Order number 08313301150Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DPA-V2 Order number 08313301151Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB55-DNA Order number 08313301160Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD10-M30EB80-DNA-V2 Order number 08313301161Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD3-M8EB60-DPS-V1 Order number 08310001648Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M8EB45-DPS Order number 08310001738Operation inductive sensor metal face DCMounting shieldedDatasheet
Name SJD2-M8EB45-DPS-V1 Order number 08310001739Operation inductive sensor metal face DCMounting shieldedDatasheet

|

Pick-Up Sensors

Special sensor group for combination with tool safety device or control unit. High-sensitive pick-up inductors record feeds on punching tools or control throw-offs of punchings.

NameOrder numberOperationMountingDatasheet
Name KJ3-G10MB12 Order number 08317061000Operation inductive sensor Pick-UpMounting shieldedDatasheet
Name KJ3-G10MB12-VK Order number 08317061100Operation inductive sensor Pick-UpMounting shieldedDatasheet
Name KJ3-G10MB12-X0309 Order number 08317061012Operation inductive sensor Pick-UpMounting shieldedDatasheet

|